L12V200ZLT-2 Natural Gas Engine Generator
Jichai Brand generating set is designed and manufactured to be high quality, long usage life, easy operation, low maintenance cost, high intelligence with low engine speed, low fuel consumption, low gas quality requirement, tough environmental adoptability, high stability and low fluctuation. The generating set is desirable for industrial power solution. The genset can either transfer electricity directly to load or be combined in a power station with two or more than two sets. They can be used as normal and stand-by power in oil field, factory, resource development base, etc.
1000GF-T(1000kW) natural gas generating set are powered by model L12V200ZLT-2 gas engine produced by our company. Complying with National Standard “GB2820 General Specification for Industrial Frequency Diesel Generating Sets(eqv ISO 8528)” and with reference to “IEC34-I” rotary generator standard, the sets are equipped with high quality alternator of both home & abroad and self-made control panel according to customers requirement.
L12V200ZLT-2 natural gas engine is adopted advanced governor of American WOODWARD Company. It is the engine that mixes air and fuel before turbocharger. The power performance, fuel economy and reliability of the gas engine reach world advanced level by adopting world advanced outer mixing mode, electronic control technology and lean-burnt strategy.
Main parameters of gas generator
Model of genset | 1000GF-T |
Model of engine | L12V200ZLT-2 |
Connecting method | Flexible coupling |
Rated speed (r/min) | 1000 |
Rated power (kW/kVA) | 1000/1250 |
Rated voltage (V) | 400/230 |
Rated frequency (Hz) | 50 |
Rated power factor | 0.8(lagging) |
Voltage regulation | AVR |
Supply mode | 3-phase, 4-wire |
Governor | Electrical controller (WOODWARD) |
Control model | Remote electric control, Hand control |
Starting method | Pneumatic motor or 24V DC motor |
Cooling method | Water cooling |
Overall dimension L×B×H(mm) | 6000×2300×2800 (for reference) |
Net weight (kg) | 17000 (for reference) |
Main parameters of gas engine
Model of engine | L12V200ZLT-2 |
Rated power(kW) | 1100 |
Rated speed (r/min) | 1000 |
No. of cylinder and layout | 12-cylinder, 60°V type |
Type | Four-stroke, water cooled, turbocharged and after-cooled, pre-mixed |
Type of combustion | Lean burn |
Gas pressure(bar) | 1~4 |
Special fuel consumption(kJ/kW.h) | ≤8700 |
Specific oil consumption (g/kW.h) | ≤0.3 |
Type of lub-oil | KCN 7805 (sulfur content<=200mg/m3) KCN 7810 (sulfur content <=460mg/m3) |
Idle speed (r/min) | 700 |
Main parameters of alternator
Rated power (kW/kVA) | 1000/1250 |
Rated voltage (V) | 400/230 |
Rated frequency (Hz) | 50 |
Power factor | 0.8 (lagging) |
Excitation model | Brushless |
Wiring method | Y, 3-phase, 4-wire |
Number of pole | 6 |
Rated speed | 1000 r/min |
Insulation class | Class H |
Protection class | IP23 |
Cooling | Fan cooling |
Bearing type, No. | Rolling bearing, 2 Pcs |
Main performance index | |
Stable voltage regulating rate | Single running: ±1% Parallel running: ±2.5% |
Instantaneous voltage regulating rate | -15%~+20% UN |
Over load | 1 hour operation time at 110% rated power (6 hours as a cycle) |
Over current multiple | 1.5IN, 2 minutes |
Ability of maintain short-circuit current | The excitation system can provide continuous current of three times of rated current, duration 5s, the alternator must be unloaded. |